• Ceritified ( ISO 9001-2015 )
+91 9370060000
+91 9822402110

Detection & Alarm System

Detection & Alarm System

Image

Temperature and humidity measurement is essential to taking control of your environment. Safe N Secure has a large variety of humidity testing and temperature monitoring devices. Choose from a selection of wireless temperature thermometers that provide data from up to 100 ft. away. For accurate readings in hard-to-reach and hazardous locations, choose an infrared thermometer with a bright laser for precise targeting.


Local Alert


A buzzer or hooter to alert the local personal incase the temperature reaches the critical level.


Auto Dialer


If the critical temperature is crossed then the auto dialer will dial to the pre programmed numbers and play the prerecorded message.


SMS


SMS will be sent to the pre programmed mobile numbers in case of an alert event.


Email


  • Daily email alerts and critical alerts can be sent.
  • Daily email alert will gives you hourly average temperature, peak and low temperature.
  • HumTemp software to configure the instrument, to generate reports.

Specification of Temperature Humidity Sensor


Humidity accuracy ±1.8%
Temperature accuracy ±0.3C
Temperature resolution ±0.01C
Humidity resolution ±0.03%
Temperature Range -40C to 123C
Humidity Range 0 - 100%
Image

We design and install the system as per the customer’s requirement. The above items are available in different makes namely - System Sensor, Apollo, Ravel, Morley, BOSCH etc.

In case of fire early detection of smoke and heat helps in fighting the fire effectively & extinguishing it in nascent stage. Thus preventing the fire from spreading and saving life and loss of property and business.


Image

In case of fire early detection of smoke and heat helps in fighting the fire effectively & extinguishing it in nascent stage. Thus preventing the fire from spreading and saving life and loss of property and business. It is a basic conventional system in which Fire Alarm Panel indicates the zone which has caught fire.


The system consists of following components

  • Fire Alarm Panel Starts from 2 zone, up to 24 zones
  • Heat Detector
  • Beam Detector
  • Intrinsically safe Thermal Detector
  • Hooter
  • Cabling
  • Detectors
  • Optical Smoke Detector
  • Flame Sensor
  • Intrinsically safe Ionization Detector
  • Manual Call Point
  • Response Indicator

We design and install the system as per the customer’s requirement. The above items are available in different makes namely - System Sensor, Apollo, Ravel, Morley, BOSCH etc.


Intelligent Addressable Fire Alarm System

Image

This is advanced system in which control panel is capable of not only knowing the detector’s location accurately but also exactly how much smoke is in the chamber of the detector.


The system consists of following components

  • Intelligent Fire Alarm Contro
  • Isolator Module
  • Communication module
  • Loop Addressable Sounder
  • Addressable Detectors
  • Loop driver card
  • Modbus
  • Manual Call Point

Information on location of the fire, fault and system status can be easily displayed or printed in multiple locations. Integration to voice Evacuation systems, Paging systems and third party control systems is supported through a range of peripheral interface units.

Following approved makes are available - Morley –IAS, Notifier, Hochiki, GE Edward, Honeywell.


Wireless Fire Alarm System

Image

Wireless Fire Alarm System is addressable and requires no cabling to be done and it indicates the accurate location of the detector fired.


The system consists of following components


  • Wireless Fire Alarm Panel ( With range of 1-2 Kms., comes in 99 zones and 999 zones with programmable detectors )
  • Wireless Detectors
  • Radio Emitter – to transmit the signal
  • Wireless Manual Call Point

Features


  • NO wiring and conduiting, works on radio waves. Lot of concealed wiring is required in case of wired system.
  • Each detector works as an independent unit. So in case of non working of particular detector it does not have any effect on the system. But in case of Wired System Complete Zone / system becomes effected due to damaging of wire or failure of connection.
  • Zero maintenance and no AMC required. Where as AMC is must and tedious job in case of wired system.
  • Immediate installations, 200 nos. of detectors with panel can be installed in a single day even when building is occupied. Approximately 20 days are required in case of wired system.
  • Can be installed in running office complex / factory etc.
  • Complete flexibility. Any time there is a requirement for any modernization of the building. Any detector / panel can be shifted as per requirements.
  • Very – very competitive prices of Wireless Addressable Fire Alarm Panel. Wired panel with equal no.s of zones cost Five times more than the wireless panel.
  • Saving of cost from 10% to 60% at the time of installations and 90% saving in running cost.
  • Easy testing while every time it is practically not possible to test the system by generating smoke. A test button is available with each wireless smoke detectors and just pressing the button is sufficient for working of detector ,panel and emitter.
  • In case of non working / failure of main control panel in wired system, whole system will be held up. But the complete system will be working in case of non working of panel.

Information on location of the fire, fault and system status can be easily displayed or printed in multiple locations. Integration to voice Evacuation systems, Paging systems and third party control systems is supported through a range of peripheral interface units.

Following approved makes are available - Morley –IAS, Notifier, Hochiki, GE Edward, Honeywell.


Aspiration Smoke Detection System

Image

The HSSD and VESDA are the internationally approved trade names for ASPIRATION SYSTEM. Aspirating Smoke Detection system (ASD) designed to give very early indication of an incipient fire condition. This pre-emptive warning – before the transition into the flaming and heat stages – provides the time necessary to take corrective action and avoid the danger, damage and disruption to operations that a fire can cause.


Aspirating Detection


The detector is mounted either inside or outside the area. It draws air from the protected area using an aspirating fan which is housed in the detection unit. The pipe network contains sampling holes at predetermined locations along the pipe network through which the air is LASER DIODE LIGHT SOURCE drawn.

Detectors can protect areas up to 2000 square metres to BS5839, or between 500 to 750 square metres to BS6266, in high air flow conditions. The pipework is configured in various ways according to the application.

Typically it will comprise a pipe network with sampling points at intervals similar to point detection. It can also, for example, be arranged to monitor across air handling units or in ducts.


Sampling pipe hart xl sampling points

  • Laser based particle counting – the superior technology
  • No recalibration during lifetime of detector
  • On site sensitivity selection 0.0025 %/m to 1 %/m
  • Configurable for integral or remote display options
  • Individual pre-alarm and alarm levels
  • Elegant, compact, lightweight design
  • No particle filters required
  • Complete flexibility – four basic sub units provide installation options
  • LaserNet networking options
  • Modular design for fast and easy servicing
  • Attachable power supply and battery back up unit

Standalone Smoke Detectors

Image

Standalone smoke detectors are used for small areas such as small office, cabins, shops etc. It gives alarm from the unit in case of fire.


The system consists of following

  • Standby Current 10 μA
  • Temprature Range 10-50 oC
  • Alarm Volume 85dB in 3meter distance
  • Unit Box 10.8x114.4cm 0.20kgs
  • Alarm Current 30 μAT
  • Alarm Density 0.65-1.55 %FT
  • ABS Fire resistance plastic case
  • Carton 65x24x39cm GW - 21.00kgs

Beam Detection System

Image

Beam detection system is ideal where the area to be protected is large , the height of ceiling is too much and where other smoke / heat detectors will be ineffective to install.


Features

  • Low cost protection of large areas
  • Quick and easy installation
  • Very low maintenance
  • Very minimum cabling required

Applications

  • Auditorium
  • Historic Building
  • Airports
  • Shopping Malls
  • Museums
  • Multiplex
  • Warehouse
  • Large Storage Areas
  • Hotel Atria

Beam Detector’s available in following brands – System Sensor, Fire Ray.

Image

Air conditioning, sprinklersystems, water cooledprocessors and heatingsystems are all potentialsources of water leakage which if undetected canseriously damage today's complex electrical, communication and computer networks even a small leak can prove disastrous.

To detect the water leakage the liquid sensing cable is installed below false flooring & above false ceiling. The control panel displays the location of the water detected by sensor cable.


An Intelligent and Addressable Sense Cable


Each sense cable is fitted with an electronic chip at one of its ends.

This manages the following functions -

  • Detects and localizes the leak of any liquid to the nearest metre along the length of the cable.
  • Addressable sense cable.
  • Detects and localizes any cut or interruption on the cable.
  • Digital transmission of all cable length data to the control digital unit.
Image

The systems detects the gas leak in the premises, pipes and protected areas. It sends signal to the panel and sounder / hooter is alarmed.

The system consists of following -

  • Gas Leak Control Panel
  • Gas Leak Detectors
  • Manual Call Point
  • Hooters Cabling

Applications


  • The high pressure LPG Storage
  • Chemical Industries
  • Gas Plant
Image

Ultrasonic pest repellers are electronic devices that emit high-frequency sounds designed to repel, injure or kill household pests, such as rodents and insects. Whether they're actually effective at doing so has been disputed by testing labs and the U.S. Federal Trade Commission (FTC).